Teaser

Signal Conditioners

We offer the appropriate interface device for separating, forming, processing, converting and conditioning analog signals. The product portfolio comprises analog signal isolators, isolating transducers, temperature measuring amplifiers, potentiometer amplifiers, trip amplifiers and level monitors - for simple and complex requirements, for Ex- and non-Ex applications, available in the IP20 housing for DIN rail as well as in the compact IP67 housing for decentralized on-site remote control.

Produkt #00091823

Products:

Short description Graphic Description
Trip amplifier
1-channel
Type: IM43-13-SR
Ident. no.: 7540041
#
  • CFMUS, TR CU
  • Monitors 3 limit values at a current or voltage input
  • Power supply of 2-wire or 3-wire transmitters/sensors
  • Input circuit: 0/4…20 mA; 0/2…10 V
  • Output circuit: 3 independent limit value relays
  • Limit value relay adjusted via TEACH button
  • Relay outputs adjusted via buttons on the front
  • Universal operating voltage
  • Complete galvanic isolation
Analog Signal Isolator
1-channel
Type: IMX12-AO01-1I-1I-H0/24VDC
Ident. no.: 7580401
#
  • ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS,
  • Installation in zone 2
  • SIL 2
  • Output circuits monitored for wire-break and short-circuit
  • Complete galvanic isolation
  • HART transparent
  • Removable screw terminals
Temperature measuring amplifier
1-channel
Type: IMX12-TI02-1TCURTDR-1I1R-CPR/24VDC
Ident. no.: 7580504
#
  • ATEX, IECEx, cFM,NEPSI, INMETRO, TR CU EAC CMI, TIIS,
  • Installation in zone 2
  • SIL 2
  • Input circuits monitored for wire-break and short-circuit
  • Parametrized via PC
  • Complete galvanic isolation
  • Removable screw terminals
  • Power bridge (connector incl. in delivery)
Trip amplifier
1-channel
Type: IM43-14-SRI
Ident. no.: 7540043
#
  • CFMUS, TR CU
  • Monitors 3 limit values at a current or voltage input
  • Power supply of 2-wire or 3-wire transmitters/sensors
  • Input circuit: 0/4…20 mA; 0/2…10 V
  • Output circuit: 0/4…20 mA, 3 independent limit value relays
  • Limit value relay adjusted via TEACH button
  • Relay outputs adjusted via buttons on the front
  • Universal operating voltage
  • Complete galvanic isolation
Temperature measuring amplifier
1-channel
Type: IMX12-TI02-1TCURTDR-1I1R-CPR/24VDC/CC
Ident. no.: 7580506
#
  • ATEX, IECEx, cFM,NEPSI, INMETRO, TR CU EAC CMI, TIIS,
  • Installation in zone 2
  • SIL 2
  • Input circuits monitored for wire-break and short-circuit
  • Parametrized via PC
  • Complete galvanic isolation
  • Removable spring type terminals
  • Power bridge (connector incl. in delivery)
Temperature measuring amplifier
1-channel
Type: IM34-11-CI
Ident. no.: 7506638
#
  • TR CU
  • Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology
  • Output circuit: 0/4…20 mA
  • Parametrized via PC (FDT / DTM)
  • Complete galvanic isolation
Temperature measuring amplifier
2-channel
Type: IMX12-TI02-2TCURTDR-2I-CPR/24VDC
Ident. no.: 7580508
#
  • ATEX, IECEx, cFM,NEPSI, INMETRO, TR CU EAC CMI, TIIS,
  • Installation in zone 2
  • SIL 2
  • Input circuits monitored for wire-break and short-circuit
  • Parametrized via PC
  • Complete galvanic isolation
  • Removable screw terminals
  • Power bridge (connector incl. in delivery)
Temperature measuring amplifier
2-channel
Type: IMX12-TI01-2RTDR-2I-CPR/24VDC/CC
Ident. no.: 7580514
#
  • ATEX, IECEx, cFM,NEPSI, INMETRO, TR CU EAC CMI, TIIS,
  • Installation in zone 2
  • SIL 2
  • Input circuits monitored for wire-break and short-circuit
  • Parametrized via PC
  • Complete galvanic isolation
  • Removable spring type terminals
  • Power bridge (connector incl. in delivery)
Analog signal isolator
2-channel
Type: IMS-AI-DLI-22-DLI/L
Ident. no.: 7504011
#
  • UL: Class1, Div 2, Group A, B, C, D; GOST
  • Input circuits: 0/4…20 mA
  • Output circuits: 0/4…20 mA
  • Accuracy < 0.1 % of full scale
  • Complete galvanic isolation
  • 6.2 mm width
Isolating transducer
2-channel
Type: IMX12-AI01-2I-2IU-HPR/24VDC
Ident. no.: 7580304
#
  • ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS,
  • Installation in zone 2
  • SIL 2
  • Input circuits monitored for wire-break and short-circuit
  • Complete galvanic isolation
  • HART transparent
  • Removable screw terminals
  • Power bridge (connector incl. in delivery)